Chemistry, Compliance & Safety, General Information

Update: Salicylate Results Reporting

Effective Wednesday, August 18, 2021, to align with Clinical and Laboratory Standards Institute (CLSI) guidelines, the Salicylate lower limit of reporting will increase from 0.3 mg/dL to 2.0 mg/dL.

Note: The therapeutic range for Salicylate is 2.0 – 10.0 mg/dL and this test is best utilized for assessment of Salicylate toxicity.

 

TEST INFORMATION

Salicylate Level – Test Codes: Epic #LAB34, Interface #10245, CPT #80329

Hemostasis/Coagulation

Update: PT/INR Resulting Change

The Spectrum Health Laboratory Coagulation Department announces the following changes occurring on 6.29.21 because of new instrumentation:

• New coagulation instrumentation will go-live on 6.29.21.

• This new instrumentation will align the Spectrum Health Regional Laboratory (in GR) with current Regional/Blodgett reportable upper limit for Protime/INR results.

• The current Protime (PT) upper limit of 120 seconds will change to 90 seconds. Any result that is greater than 90 seconds, will be reported as >90 seconds.

• The current INR upper limit of 12.0 will change to 8.0. Any result that is greater than 8.0 will be reported as >8.0.

Any questions can be directed to the Spectrum Health Regional Laboratory Coagulation Department using the Contact Us link above.

TEST INFORMATION 

PT/INR (Protime with INR): Epic Code #LAB320 | Interface code #10059 | CPT #85610