In both the inpatient and outpatient settings, the laboratory has supplied 24 hour urine containers with preservative such as acetic acid, sodium hydroxide, and boric acid. Upon review of specimen stability requirements, it has been determined that a preservative is not needed prior to collection of most 24 hour urine tests as long as the 24 hour container is kept refrigerated or on ice during the collection period.
Laboratory Services
Effective Monday, March 25, 2019, Syphilis Antibody Screen IgG [LAB3076] will change to Syphilis Total Antibody Screen [LAB1230501]. This test is also included in the Prenatal Screen (OB Panel) [LAB1230094].
Spectrum Health has been informed by Roche Diagnostics that the proprietary reagents used to calibrate our instruments and determine control values for ferritin blood level have been updated to reflect deviation of results leading to low result bias. This may have led to patient results being up to 20% lower than actual ferritin level.
Reference Range Update – OB Magnesium, Blood Level
Effective immediately, the OB Magnesium (Mg) reference range has been updated from 1.6 to 2.5 mg/dL to 4.8 to 8.0 mg/dL, to reflect the correct therapeutic range for patients receiving magnesium sulfate therapy. The non-OB magnesium reference range is unchanged.
Please direct questions and inquiries to Dr. Jennifer Stumph via the Contact Us link above.
TEST INFORMATION
OB Magnesium, Blood Level – Epic code #LAB3400, Interface code #11703, CPT code #83735
Reminder: Choosing Wisely Recommendations for Blood Products
As part of the Choosing Wisely campaign, the American Association of Blood Banks (AABB) released five recommendations for transfusions:
For Hemoglobin A1c testing, Mayo Clinic Laboratory has switched to an Ion-Exchange High-Performance Liquid Chromatography (HPLC) method (Bio-RAD D100) which is the same method of A1c testing used at Spectrum Health Regional Laboratory. They no longer offer the alternative method, boronate affinity chromatography, for A1c testing.
When A1c cannot be determined due to interferences that affect the Bio-RAD 100 method, measurement of serum fructosamine is recommended (Mayo test FRUCT).
NEW TESTS
- Drug Screen with Confirmation (23 Targets) [Epic: #LAB1230496; Interfaced: #1230496]
- Drug Screen with Confirmation (32 Targets) [Epic: #LAB1230497; Interfaced: #1230497]
DISCONTINUED TESTS
Effective January 19, 2019, Spectrum Health Regional Laboratory – Toxicology is proud to announce the availability of two new drug screen panels:
Effective December 3rd, 2018, the test code for ANA Screen [LAB147] will be discontinued and replaced with ANA Screen Double Reflex [LAB1230491].