Effective Date: December 2, 2026
Overview of Change
On December 3, 2025, Corewell Health West transitioned the primary specimen type for outpatient potassium testing from plasma to serum. Because potassium concentrations differ slightly between serum and plasma due to the clotting process, this transition required a corresponding update to our established potassium reference range.
Effective December 2, 2026, the laboratory will update the reference range for potassium testing. This update aligns our reporting intervals with our recent transition in preferred specimen type from plasma to serum.
| Analyte | Previous Reference Range (Plasma) | New Reference Range (Serum) |
| Potassium | 3.4 – 5.0 mmol/L | 3.5 – 5.2 mmol/L |
Reason for Change
- Specimen Optimization: Serum provides a cleaner specimen matrix with reduced interference and fewer pre-analytical artifacts. Standardizing to serum aligns with the preferred collection workflow for our outpatient cohort and improves overall sample quality and operational efficiency.
- Reduction of False Elevations: Potassium concentrations are slightly higher in serum than in plasma (approx. 0.4 mmol/L) due to the release of potassium from platelets during the clotting process. Applying the legacy plasma reference range to serum samples has resulted in an elevated rate of falsely high potassium flags. Updating the reference interval to reflect serum-specific baselines will directly alleviate these false-positive elevations, decreasing the rate of abnormal flagging by around 50%.
Best practices
Although multiple factors can elevate serum/plasma potassium concentrations, the following highlights factors with the greatest impact and recommended best practices to help avoid pseudohyperkalemia:
- Do not allow re-centrifugation of barrier tubes.
- Do not allow fist clenching during collection.
- In compromised gel barriers, leakage of potassium can occur.
- Use double-gel transport tubes (SST) from outside the hospital.
- Allow specimens to clot completely before centrifugation, generally 20–30 minutes.
- Use a swing-arm centrifuge to minimize gel barrier disruption and follow the manufacturer-recommended speed and time.
- Gently invert the tube several times after collection to ensure the clot activator is adequately mixed with the blood.
- Centrifuge and aliquot samples promptly.
- Respect the order of draw to avoid sample contamination (see Corewell Health Policy 9952, bullet point 5, step 8).
To reduce the incidence of artifactual hyperkalemia, the laboratory is currently conducting re-education for phlebotomy staff across all practices performing on-site venipunctures.
Recommendations
Result Interpretation: Please evaluate patient results using the new serum reference interval printed on all reports generated on or after December 2, 2026.
Questions?
For questions or additional information, please contact:
- Bill Chopp, MD, Laboratory Medical Director – Corewell Health West
- Yasel Fleitas, PhD, Technical Director, Clinical Chemistry
- Alex Castillo, MT(ASCP)CM, Manager, Hospital Laboratory
Or you may contact your local Laboratory Customer Service Department or Laboratory Account Manager:
- Southeast Michigan: 800.551.0488
- Southwest Michigan: 269.983.8311 ext 1
- West Michigan: 616.774.7721

No Comments