Chemistry, Education & Training, Main lab

Test Update: AST and ALT

Go Live Date delayed to 3/3/2022

Go-Live Date: 3/2/2022

Due to new instrumentation at Spectrum Health Blodgett Hospital Laboratory (BIRL) and to standardize across the Spectrum Health system, we will be adopting new tests for AST and ALT. The difference between our current test and this new test is the addition of the co-factor pyridoxal phosphate (Vitamin B6). The new test is the recommended test of the International Federation of Clinical Chemistry and ultimately will provide our patient population more accurate AST and ALT results. We did not adopt the new test in the past because it came with logistical and stability issues that made its use in the lab difficult. The new instrumentation we obtained has solved some of these concerns.

Historically, if patients had a Vitamin B6 deficiency, their AST and ALT levels may have been falsely lower than the true values. This decrease was due to the lack of endogenous co-factor causing a slower reaction rate when we tested the patient sample. After we implement the new test across the system, you may notice an increase in your patient’s AST and ALT results. This increase may be evidence that your patient had some degree of Vitamin B6 deficiency. If you were trending results, we recommend you establish a new baseline with the new test versions. The lab has been changed slightly in EPIC to prevent trending between the two test versions, since the results may not be able to be correlated if your patient had a Vitamin B6 deficiency. Continue Reading

Chemistry, General Information, Immunochemistry

Test Update: Rubella IgG Antibody Testing

On January 24th, 2022 Rubella Antibody, IgG, Serum (LAB496) and Rubella IgG Antibody Quantitative (LAB3544) will be combined as LAB496 and moved to the Immunochemistry laboratory due to reagent constrains with the current vendor.

Testing will be available Monday-Friday with a turn-around-time of 1-3 days. Results will be reported qualitatively as Immune or Not Immune.  If quantitative results are needed, please fax Immunochemistry at 616-267-2771 or call 616-267-2770. Continue Reading

Molecular Diagnostics

Cystic Fibrosis (CF) Carrier Screen Discontinued

Effective February 1, 2022, the Cystic Fibrosis (CF) Carrier Screen test, which includes the 23 common variants for cystic fibrosis recommended by ACOG/ACMG, will be discontinued as an orderable test at Spectrum Health Laboratory.

The recommended replacement test is the Cystic Fibrosis Mutation Analysis (Test ID: CFP) offered by Mayo Clinic Laboratories, a 106-variant panel which includes the recommended 23 common variants.

Continue Reading

General Information, Hematology

Test Update: Cell Count with Differential, Body Fluid

Beginning Tuesday, January 4, 2022, Spectrum Health Laboratories will include an automated neutrophil (PMN) count on Cell Count with Differential, Body Fluid (LAB210) orders for peritoneal body fluids.   This component will be displayed in Epic as an absolute PMN count, body fluid.

• The absolute PMN count in the peritoneal fluid is calculated by multiplying the total nucleated cell count by the percentage of PMNs in the differential.

• This calculation aids in the diagnosis of spontaneous bacterial peritonitis (SBP).

• The diagnosis of bacterial peritonitis is established by a positive peritoneal fluid bacterial culture and an elevated peritoneal fluid absolute PMN count (≥250 cells/uL).

• Epic will automatically calculate the absolute PMN count in peritoneal body fluids based on the manual differential data.

• This component ONLY calculates for Cell Count with Differentials (LAB210) on PERITONEAL BODY FLUIDS Continue Reading

Hemostasis/Coagulation

New Test: Thrombin Time

Effective March 4th, 2020, Thrombin Time will change from a sendout reference test performed by Mayo Clinic Laboratories to an in-house test performed by Spectrum Health Regional Laboratory. This test will be performed in the Coagulation Laboratory and will include a new reference range (please see link in Test Information below).

Thrombin Time is suitable for monitoring fibrinolysis therapy, screening for disorders of fibrin formation and in cases of suspected fibrinogen deficiency states. It is also useful for the differentiation between a heparin induced prolongation of the thrombin time and fibrin formation disorders.

For questions around this test, please contact the Coagulation Department at 616-267-2740.

TEST INFORMATION

Thrombin Time – Epic Code: #LAB11230581, Interface Code: #11230581, CPT: #85670