Browsing Tag

Pediatrics

Chemistry, General Information

Test Update: Thyroglobulin Antibody

Effective immediately, Thyroglobulin Antibody will be performed at Spectrum Health Reference Laboratory (SHRL, Grand Rapids, MI) and will no longer be a sendout to Mayo Clinical Laboratories. Collection instructions and other information may have changed, please visit the lab catalog for more information.

Thyroglobulin Tumor Marker will continue to be a sendout. If a Thyroglobulin Antibody is ordered with a Thyroglobulin Tumor Marker, then the Thyroglobulin Antibody will automatically be canceled as Mayo Clinic Laboratories will perform the Thyroglobulin Antibody as well as the Tumor Marker.

For questions and inquiries, please use the “Contact Us” link above.

 

TEST INFORMATION

New test: Thyroglobulin Antibody [LAB1230840] 

Former test: Thyroglobulin Antibody, Serum [LAB1230457]

Mentioned Test: Thyroglobulin, Tumor Marker, Serum [LAB864]

Advanced Technology Laboratory, General Information, Main lab, Test Utilization

Outpatient Respiratory Viral Testing

Spectrum Health Lab has noticed an increase in outpatient orders for Respiratory Pathogens by Film Array [LAB3359].  This may be due to a shortage of supplies for some Point of Care (POC) testing platforms.  Film Array is typically used for emergency and high acuity patients and therefore has a high cost that may not be covered by most patients’ insurance.  To lesson out of pocket costs for your patients, please order the below for RSV, COVID, or Flu testing. Continue Reading

Chemistry, General Information, Test Spotlight

Sysmex Urinalysis Series Go Live

In continued pursuit of alignment, regional market hospital labs have adopted the Sysmex-Siemens automated urinalysis system. This advanced platform elevates analytical control and automation, eliminates manual steps previously required from former systems, and offers the latest in digital particle imagery. Combined with exceptional service engineer support, this system represents a notable step forward in urinalysis performance. Continue Reading

Main lab, Microbiology, Test Utilization

Influenza Testing Reminder

The mitigation strategies enacted during the COVID-19 pandemic to reduce the spread of this virus have also impacted the transmission of other respiratory viruses. Influenza is typically prevalent during the winter months (December through March), however, influenza cases were essentially non-existent during the 2020-2021 season and influenza is not currently circulating in our community.

In the absence of circulating influenza activity, it is recommended to use the most sensitive diagnostic test in order to obtain accurate and actionable results. Influenza antigen testing (e.g. Sofia instrument) is not appropriate at this time. More detailed information can be found as published by the CDC: Algorithm to assist in the interpretation of influenza testing results and clinical decision-making during periods when influenza viruses are NOT circulating in the community

Low Influenza
prevalence
High influenza
prevalence
Recommended order Influenza PCR (LAB3255) Influenza Rapid Antigen (LAB2111530)
or
Influenza PCR (LAB3255)

TEST INFORMATION

Test name Epic code Interface EMR Code CPT Code
 Influenza PCR  LAB3255 11594 87502
 Influenza Rapid Antigen  LAB2111530 11208 87804 x4
Hemostasis/Coagulation

New Test: Factor VIII Chromogenic Assay

Effective July 1, 2021, the Coagulation Department within the Spectrum Health Regional Laboratory will go live with an in-house, bovine based, Chromogenic Factor VIII assay.

This assay, a photometric determination of Factor VIII activity, is useful for monitoring coagulation factor replacement therapy of selected extended half-life coagulation factor replacements and Emicizumab therapy, a recombinant, monoclonal antibody that restores the function of the missing activated factor VIII by bridging FIXa and FX. The action of Emicizumab interferes with all APTT clot based and human chromogenic based assays, leading to an overestimation of Factor VIII activity.  As such, the bovine based Chromogenic Factor VIII assay is recommended.  The Chromogenic Factor VIII activity also assists in the diagnosis of hemophilia A using a 2-stage assay, particularly when the 1-stage clot based assay is normal.

For questions about this test, please refer to the laboratory catalog or use the Contact Us link above.

TEST INFORMATION

Chromogenic Factor VIII Activity – Epic Code: LAB1230831 | Interface Code: 1230831 | CPT: 85240

Advanced Technology Laboratory, General Information, Main lab

Update: COVID-19 Swab Supplies

If you are collecting COVID-19 swabs in your office or clinic, please order and collect using the saline swab kits (“liquid media” or “wet collection”) instead of the tube with no liquid media (“dry collection”).

• Liquid media swab kits will provide a faster turn-around time.

• Dry collection kits supplies are low.

Please refer to the COVID-19 PCR test in the Lab Catalog for the most up-to-date information on COVID-19 collection.

COVID-19 PCR Swab – LAB1230607

Continue Reading

Compliance & Safety, Education & Training, General Information

Self-Collected Swabs

Self-collected vaginal swabs may be used for testing as opposed to provider-collected swabs. Self-collected swabs are supported by current clinical guidelines as recent studies have shown their equivalence, if not superiority, in quality and their association with increased patient satisfaction.

NOTE: Self-collection must still take place in a healthcare setting and is not approved for at-home collection.

Continue Reading

General Information, Immunochemistry, Test Spotlight

New Insect Allergen Component Testing

Effective December 9, 2020, the following insect allergen components will be available:

Allergen Honey Bee Component Panel – EPIC #LAB1230747, Interface #1230747, CPT 86008

Allergen Common Wasp (Yellow Jacket) Component Panel – EPIC #LAB1230752, Interface #1230752, CPT 86008

Allergen Paper Wasp Component rPol d 5 – EPIC #LAB1230754, Interface #1230754, CPT 86008

Cross-reactive Carbohydrate Determinant (CCD) – EPIC #LAB1230755, Interface #1230755, CPT 86008 Continue Reading

Hemostasis/Coagulation

New Test: Thrombin Time

Effective March 4th, 2020, Thrombin Time will change from a sendout reference test performed by Mayo Clinic Laboratories to an in-house test performed by Spectrum Health Regional Laboratory. This test will be performed in the Coagulation Laboratory and will include a new reference range (please see link in Test Information below).

Thrombin Time is suitable for monitoring fibrinolysis therapy, screening for disorders of fibrin formation and in cases of suspected fibrinogen deficiency states. It is also useful for the differentiation between a heparin induced prolongation of the thrombin time and fibrin formation disorders.

For questions around this test, please contact the Coagulation Department at 616-267-2740.

TEST INFORMATION

Thrombin Time – Epic Code: #LAB11230581, Interface Code: #11230581, CPT: #85670