Anion Gap Reference Range Update

Effective February 7, 2024, at 7:30 AM, Corewell Health West Laboratories will go live with a new reference range for the calculated Anion Gap (AG). The AG reference range will be adjusted to align with recent reference range studies.

The following will be the new normal reference ranges for AG:

Anion Gap: 5 – 14 mmol/L

 

Continue Reading

Immunochemistry, Main lab

Update in Testing Platform – Immunochemistry

As of January 26, 2024, for the following tests, the testing platform has changed from EliA Fluorescence Enzyme Immunoassay (FEIA) from Thermofisher to Multiplex Flow Immunoassay from Biorad. Please review the lab catalog for any changes to collection information or reference ranges.

• Anti-dsDNA Antibody
• Cyclic Citrullinated Peptide (CCP) Antibody
• Celiac Antibody Cascade
• Tissue Transglutaminase Antibody
• Gliadin Antibodies Continue Reading

General Information

Albumin Testing Update

Albumin Reagent Conversion

Corewell Health Laboratories (formerly Spectrum Health) has utilized the Bromcresol Purple (BCP) method for the measurement of albumin concentration in serum, plasma, and serous body fluids for well over 20 years. The test principle consists of a reaction where the BCP binds selectively with albumin, causing a color change that is measured photometrically. A vast majority of labs across the country, including reference labs such as Mayo Medical Laboratories, utilize an alternative method for albumin measurement that consists of Bromcresol Green (BCG) instead of BCP. To align with the majority of institutions this size, and to be included in a larger peer group for proficiency testing purposes, Corewell Health Laboratories – West, has been transitioning to BCG for the measurement of albumin over the last few weeks. Continue Reading

Chemistry

Reference Range Update: ALT and AST

After consultation with our clinical partners, Spectrum Health West Michigan Laboratory will be adjusting the pediatric reference ranges for our new ALT and AST reagents in an effort to better serve our population.  Numerous academic studies were reviewed, and the values listed below were adopted on August 3, 2022: Continue Reading

Chemistry

Updates: Chemistry Reference Ranges

Effective August 2, 2022, reference ranges for the below tests will be updated to better align with the vendor’s recommendation and with Spectrum Health Lakeland Laboratory. Please click on the links below and scroll to the Reference Range field to see the updated ranges.

Lithium Level [LAB29]

PTH Intact [LAB108]

IgM Level [LAB72]

IgA Level [LAB73]

CA 125 Level [LAB155]

C4 Complement Level [LAB151]

C3 Complement Level [LAB152]

Albumin Level [LAB45]

Transferrin Level [LAB133]

Questions or inquiries may be directed to the “Contact Us” link above.

General Information, Hemostasis/Coagulation

Test Update: Prothrombin Time (Protime/PT)

Effective December 6, 2021, Spectrum Health Reference Laboratory (SHRL) Coagulation department will go live with a new lot of Prothrombin Time (Protime/PT) reagents. The reference range for the PT will be adjusted to reflect this reagent lot change and align with our Regional Laboratories. The new reference range will be 9.5 – 12.0 seconds. There will be no change to the INR ranges.

Test Current Reference Range New Reference Range
Prothrombin Time (PT) 9.7 – 12.6 seconds 9.5 – 12.0 seconds

Continue Reading

Hemostasis/Coagulation

aPTT Range Update for Heparin Nomograms

On Tuesday October 26, 2021, a new lot of aPTT reagent will go live for the Spectrum Health Laboratory Information System starting at 10:00 AM.

• The aPTT therapeutic range for ADULT patients on continuous heparin infusions will be updated to reflect the new reagents.  The therapeutic range, for most indications, will be changed from 37 to 52 seconds to a new range of 42 to 57 seconds. UFH anti-Xa therapeutic ranges will remain unchanged (0.3 to 0.7 units/mL).  All ADULT nomograms will be adjusted to reflect the new therapeutic ranges.

• For PEDIATRIC  patients, aPTT nomograms will no longer be used in this population. Only the unfractionated heparin (UFH) anti-Xa nomograms will remain for PEDIATRIC patients, again with no changes made to their current UFH anti-Xa nomograms.

The aPTT reference range remains unchanged. Continue Reading